AquaShieldPro B26

Share
Login to earn Coins for sharing!

Non-fibrated, clay-filled, solvent-free, flexible, bitumen emulsion paint for general purpose

In stock
Only %1 left
SKU
ASPB26

Quantity Calculator

Product Pack Size Coverage Unit Total Requirement No of units Required
AquaShieldPro B26 (125 Microns)-(Ist Coat) 15 0.20 ltr/m2
AquaShieldPro B26 (125 Microns)-(2nd Coat) 15 0.20 ltr/m2
AquaShieldPro B26 (125 Microns)-(Ist Coat) 100.00
AquaShieldPro B26 (125 Microns)-(2nd Coat) 0.00
Price/Sqm

*This Coverage Is Theoretical & Depends Upon The Surface Profile Of The Substrate & The Wastage.
*Coverage Rates Given Refer To This Project Only.
*Wastage Of Material And Preparation Of Surface Not Included.

Product Pack Size Coverage Unit Total Requirement No of units Required
AquaShieldPro B26 (125 Microns)-(Ist Coat) 200 0.20 ltr/m2
AquaShieldPro B26 (125 Microns)-(Ist Coat) 200 0.20 ltr/m2
AquaShieldPro B26 (125 Microns)-(Ist Coat) 100.00
AquaShieldPro B26 (125 Microns)-(Ist Coat) 0.00
Price/Sqm

*This Coverage Is Theoretical & Depends Upon The Surface Profile Of The Substrate & The Wastage.
*Coverage Rates Given Refer To This Project Only.
*Wastage Of Material And Preparation Of Surface Not Included.

Where To Buy
DATA RESULT
Appearance Thick viscous
  Dark Brown/ Black Liquid
Density (ASTM D 1475) 1.05 ± 0.05 (g/cm³)
Solid Content by weight 26±2%
(ASTM D2369-10)  
Wet film thickness 400 microns
Touch free time 20-30 minutes
Drying Time @ 25º C 6–8 hrs per coat
Overcoating Time 4-24 hours
Application Temperature +5º C to +55º C
Service Temperature -10º C to +85º C
pH Value 10-Nov
Flash Point Non-Flammable
VOC Content < 30 g/ liter

Description

AquaShieldPro B26 is a single pack, cold applied, stable water-borne bitumen emulsion coating of brushing consistency that dries to form a firm, flexible, black jointless vapor barrier coating. and tough protective coating for concrete.

Additional Information

Applicable Standards/ Compliance: Packaging: Colors: Coverage/ Yield:
Contributes toward satisfying  LEED® v4 requirements of the EQ Credit- Low-emitting Materials (for the VOC content). 15 liters pail & 200 liters drum Dark brown (liquid)Black (dry) The average dry film thickness of 125 microns was achieved when applied @ 3-5 m²/litre/coat, at the required number of coats

 

Typical Applications

  • Water-based bitumen emulsion, suitable for protection and

  • Generally used as all-purpose bituminous primer on steel
    and concrete, prior to the application of torch applied
    membranes and protective coatings, to increase adhesion
    and bond to the substrate
  • Seal newly cut timber surface to prevent loss of moisture
    Damp Proofing for below ground concrete structures and
    foundations which are above the water table
  • Protective coating for built-up roofing systems and other
    exposed surfaces
  • Moisture vapor barrier on block works and waterproofing
    concrete surfaces prior to cladding
  • Waterproofing wet areas (horizontal concrete structures
    below screeds isolated with PE sheets)

Benefits

  • Single component, solvent free
  • Cold applied, no heating required
  • Suitable for new and old concrete
  • Vapour permeable allows substrate to breathe
  • Resists the attack of salts like chlorides and
    sulphates that are present in soil
  • Simple and easy to apply, no skilled labour
    required
  • Ready to use by brush or roller
  • Non- slumping
  • Excellent adhesion to concrete, metal, wood,
    cork and most common building substrates
Technical Data Sheet Download
Test Reports Download
Substrate Preparation

The surface to be treated should be clean, dry, and free from dirt, oil, and grease. All surfaces where bitumen coating is to be applied must be thoroughly cleaned. Remove all dust, dirt, or contamination to get sound clean, dry surfaces. All major cracks are to be opened in a “V” shape & fill up with the RepairPro range of repair mortars. Honeycombed or spalled concrete is to be repaired with a suitable repair mortar. Nail heads and other protrusions that are likely to damage the coating must be removed or grounded. Old concrete and steel must be structurally sound prior to application.

Product Preparation

The drum should be rolled on the ground back and forth before decanting the material. Stir the contents of the drum thoroughly prior to application

Priming

Primer is always recommended prior to the coating as it not only penetrates into the concrete pores and seals the substrate. It also acts as an adhesion promoter for further coatings. The primer coat can be made on the site by diluting the same product with 20% water & applying this diluted coat as a primer. The primer may be applied by a brush, roller, or airless spray. Allow the primer to dry before any further coats are applied. However, if the primer after the application is left open for more than 24 hours after it becomes dry, clean the surface of any settled dust & apply a fresh coat of the primer.

Product Application

AquaShieldPro B26 should be applied by roller, brush, airless spray, or squeegee to prepared surfaces. Stir well before use, and replace the lid when not in use. For any spillage soak up with sand or sawdust and wash down immediately. As a damp-proof membrane and vapor barrier, two coats of AquaShieldPro B26 is recommended. Allow a minimum of 4 hours between the first coat and second coat. Second and subsequent coats should be applied at right angles to each other once previous coats have fully dried. All applications should be continued up verticals to the existing damp proof course. Where the surface is to receive a plaster finish, render or screed, ‘grit’ the second coat with clean, dry sand to form a keyed surface. After drying the excess sand should be brushed off. Allow a minimum of 7 days drying period before applying plaster, render, or floor screed The coating shall be protected from ongoing site activities & during backfilling from getting damaged by polyethylene sheet.

 

Cleaning:

Clean all tools immediately after use with clean water. Hardened material can be cleaned with a solvent.

Others
  • Try to avoid application during the hottest times of the day, and in direct sunlight.
  • Do not proceed with the application when rainfall is imminent unless in a sheltered or protected situation.
  • Do not use the product to waterproof structures exposed to UV rays
  • Do not use the product to waterproof structures with water under pressure
  • The substrate temperature must be at least 3°C above the dew point to reduce the risk of condensation.
  • The substrate moisture content must be ≤ 5% moisture content, no rising moisture
Write Your Own Review
You're reviewing:AquaShieldPro B26
Your Rating