Ready to use, acrylic-based, one-component, liquid applied, elastomeric waterproof membrane

In stock
Only %1 left
SKU
ASPAC

Quantity Calculator

Product Pack Size Unit Coverage Total Requirement No of units Required
AquaShieldPro AC (250 Microns)-(Ist Coat) 15 kg/m2 0.60
AquaShieldPro AC-(250 Microns)-(2nd Coat) 15 kg/m2 0.60
AquaShieldPro AC (250 Microns)-(Ist Coat) 0.00
AquaShieldPro AC-(250 Microns)-(2nd Coat) 0.00
Price/Sqm

*This Coverage Is Theoretical & Depends Upon The Surface Profile Of The Substrate & The Wastage.
*Coverage Rates Given Refer To This Project Only.
*Wastage Of Material And Preparation Of Surface Not Included.

Where To Buy
DATA RESULT
Colour White & Grey
Density (g/cm³) @ 25º C 1.25
(ASTM D 1475)  
Dry solids content (%) 54±4
Wet film thickness 500 microns
Tensile strength 0.5 - 1.0 MPa
Elongation 500 - 600%
Crack Bridging > 0.75mm @ 0.6mm DFT
Water Penetration Nil @ 20m head
Tack Free Time 3 hours @ 20º C
Recoat time 6-24 hours @ 20º C
Full Dry 72 hours @ 20º C
Application Temperature From +5º C to +40º C
Service Temperature From -10º C to +60º C
VOC content <15 g/ liter

Description

AquaShieldPro AC is a liquid-applied, ready-to-use, acrylic copolymer-based dispersion that dries to form a seamless elastomeric waterproof membrane. The cured membrane provides a breathable and waterproof elastomeric barrier with crack bridging properties representing the safest option for both permanent and temporary exposed roofs.

Additional Information

Applicable Standards/ Compliance: Packaging: Colors: Coverage/ Yield:
Complies  with  the  relevant  sections  of 15 kg bags White and Grey Yield: 12 liters / 15 kg unit
ASTM C836 Coverage: 0.6 kg/m² per coat (2 coats recommended)
Conformity with  LEED v2009 IEQc  4.2:      
Low-Emitting   Materials   -   Paints   and     Total consumption: ≥ 0.9 - 1.4 kg/m² (≥ 0.6 - 1.0 l/m²)
Coatings     Dry film thickness: ≥ 0.3 - 0.5 mm
Conformity  with  LEED  v2009  SSc  7.2     * Actual coverage will depend on wastage and surface profile and
(Option 1): Heat Island Effect - Roof     can be up to 20% or higher than theoretical coverage.

Typical Applications

  • For roof waterproofing solutions in both new construction and refurbishment projects
  • For wet area waterproofing (under-tile) in Bathrooms, Kitchens, Balconies
  • As a waterproof and protective coating on top of spray polyurethane foam roof insulation.
  • For cost-efficient life cycle extension of failing roofs
  • For a reflective coating to enhance energy efficiency by reducing cooling costs

Benefits

  • One-component - ready to use
  • Cold applied - requires no heat or flame
  • UV resistant and UV stable
  • Highly elastic and crack-bridging properties.
  • Seamless waterproof membrane system.
  • Can be used vertical and horizontal
  • Easily recoated when needed - no stripping required
  • Low VOC emitting water-based coating
  • Excellent adhesion on porous and non-porous substrates
  • Water vapor permeable - Breathability allows the release of trapped moisture.
  • Durable, low maintenance costs, easy to repair
  • Specially formulated for use in Middle East conditions.
  • VOC compliant
  • Easily applied by brush, roller, squeegee, or airless spray
  • Solvent-free
Technical Data Sheet Download
Substrate Preparation

All surfaces should be clean, sound, dry, well cured with no rising dampness and free from grease, oils, curing membranes, laitance and any loose particles. Surfaces should be slightly rough and any laitance removed by wire brushing or water jetting.

Before applying AquaShieldPro AC, pay particular attention to expansion joints and fillet joints between horizontal and vertical surfaces. Structural joints must be waterproofed with apply a suitable elastomeric joint band bonded in place with RepairPro EP FC.

Movement Joints:

All connections between the substrate and pipe entries, plant and equipment, light switches etc., must be sealed and watertight. Joints in concrete, pipes or anywhere else in the structure must also be sealed and made watertight. All expansion and movement joints should be sealed with a suitable joint sealant. When sealant is cured, a non-adhesive debonding Tape should be applied loose over the joint. One primer coat of AquaShieldPro AC thickness should be applied to the substrate to a distance 100mm either side of the tape and allowed to dry. A single coat of AquaShieldPro AC should be applied over the joint area, extending 100mm beyond each side of the tape, and while wet, reinforced using 100% non-woven, virgin polypropylene mesh fabric and allowed to dry.

A second 1mm thick coat should then be applied. Special consideration to detailing of expansion joints, construction joints, all penetrations and at changes of direction (vertical and horizontal) using recommended mesh

After the recommended mesh has been applied, finish off the surface with a flat trowel and apply a second coat of AquaShieldPro AC. Successive coat must only be applied when the previous coat is dry

Before applying AquaShieldPro AC, pay particular attention to expansion joints and fillet joints between horizontal and vertical surfaces. Structural joints must be waterproofed with apply a suitable elastomeric joint band bonded in place with RepairPro EP FC.

Coving and bends:

Use coved details at the floor/wall junctions. All angles / bends must have a cant strip or coving detail installed. This may be formed using a sand/ cement mix. One primer coat of AquaShieldPro AC should be applied, extending 150mm either side of the coving and pre-soak the reinforce using recommended mesh while still wet and allowed to dry. A second coat should be applied.

All protrusions and stress points should be pretreated with a single coat of AquaShieldPro AC extending 150mm either side of the detail. Reinforcement using recommended mesh is recommended where movement is possible, using the same technique as above.

All pretreatment coats must be allowed to dry before the main application of AquaShieldPro AC

Primer

Before applying AquaShieldPro AC

  • Use BondPro Grip Primer for old ceramic, porcelain and natural stone floors.
  • Use BondPro Penetrating Primer for very porous substrates like gypsum boards, cement boards and anhydrite screeds

Mixing

AquashieldPro AC is a single component but stirring of the pail is recommended prior to the application of the coating. This will remove any sediment which may occur during storage. The use of a slow speed drill and suitable paddle should be used in order to avoid the formation of air bubbles.

 

Product Preparation

Prime using a 50:50 mix of AquaShieldPro AC and clean water. Allow to become tack free for at least 30 minutes and then apply AquaShieldPro AC.

Product Application

Apply the product by brush, roller or spray. Two coats are recommended. The first coat should dry (see recoat times) before the second coat is applied diagonally to first coat.

Once the membrane is dry, further trades can commence

If AquaShieldPro AC is applied to form an anti-fracture membrane on cracked substrates, we recommend inserting reinforcement mesh in to the first coat while it is still fresh. The mesh must be pressed down with a bubble-breaker roller on the first coat of AquaShieldPro AC while it is still fresh. Wait until the first coat is dry then apply the second coat in order to completely embed the mesh. Drying times may increase as the use of the mesh insertion increases the final thickness of the applied film

Cleaning:

Tools, equipment and mixers with clean water immediately after use (before hardening) using soapy water. Cured material can be removed mechanically.